CPC

Sealing Plug HFC39

ITEM # HFC30039M-10

Sale

At a Glance

The HFC Disconnect Series enables sterile disconnection of single-use biopharma and cell and gene therapy manufacturing systems. With an easy push of the connector thumb latch, sterility is maintained on both sides of the system during the disconnection process. Ideal for disconnection from storage/mixing tanks, SU bioreactors, transfer lines, chromatography skids, filters, sampling, and freeze/thaw bags. Sold in the connected set, including a protective thumb latch cover, eliminating the chance of an accidental disconnection. Laser etched with item and lot number for batch traceability.

Pricing (Based on quantity)

Quantity Price / Unit
MRP $247.39
Sale $210.28 /unit
Total $210.28
MRP $247.39
Sale $210.28 /unit
Total $210.28

Add to your cart to unlock

Add to your cart to unlock

Pack Size

Made to Order
This item is made to order and ships in 2–4 weeks.
Request a Bulk Quote
We offer a special pricing program — create a free account to unlock an additional 5% off, then browse and shop at your account price. Create a free account

Every Product. Every Penny.

Risk-free with our 100% Money-Back Guarantee.

Always Free Expert Advice

Our Tech Team is happy to help!

Real People. No Robots.

Calls connect to a human within 9 seconds.

300K Customers Strong

Products used in 100 countries on 7 continents.

Download Datasheet

Sterile Polysulfone Sealing Plug for Single-Use Biopharma Manufacturing Connection Systems

The HFC Disconnect Series enables sterile disconnection of single-use biopharma and cell and gene therapy manufacturing systems. With an easy push of the connector thumb latch, sterility is maintained on both sides of the system during the disconnection process. Ideal for disconnection from storage/mixing tanks, SU bioreactors, transfer lines, chromatography skids, filters, sampling, and freeze/thaw bags. Sold in the connected set, including a protective thumb latch cover, eliminating the chance of an accidental disconnection. Laser etched with item and lot number for batch traceability.

Features

  • Intuitive one-step disconnection process: Minimize operation error and eases standard operation procedure creation and training.
  • Ease of connectivity: No requirement for additional equipment to make sterile disconnection.
  • Audible "CPC click": Provides confidence of a secure connection.
  • Protective thumb latch cover: Eliminate accidental disconnects.
  • Laser etched item number and lot number: Full traceability to raw material source.
  • Alloy C-276 internal flow path spring: Enabling broader application compatibility.

Applications

  • Media and buffer transfer
  • Sampling
  • Filtration process
  • Harvest and collection
  • Upstream and downstream connections

Specifications

Operating Conditions (Fluid Transfer):
Pressure Up to 75 psi, 5.17 bar
Temperature 34°F (1°C) to 104°F (40°C)
Materials:
Main Components Polysulfone (amber tint)
O-rings Silicone (clear), platinum-cured
Flow Path Springs Alloy C-276
Sterilization:
Gamma Up to 50 kGy irradiation. Sterilize coupled or uncoupled
Autoclave Up to 270°F (132°C) for 60 minutes. One cycle.
CV Value:
HFC Disconnect 1/4" CV Value 0.77
HFC Disconnect 3/8" CV Value 1.1
HFC Disconnect 1/2" CV Value 1.9
Cv values are based on gpm and psi, and lpm and bar (shown in parentheses).

Videos

Videos Coming Soon!

Shipping & Returns

30-day returns

Ships in 2–4 weeks. Returns accepted within 30 days of purchase.

You pay
$210.28 /unit
Frequently Bought Together

Frequently Bought Together

Lab safety professionals recommend pairing these items

Powered by Search & Discovery
Sealing Plug HFC39
MRP $247.39
Sale $210.28

Bundle Summary

 items selected
Sealing Plug HFC39

Price Breakdown

Sealing Plug HFC39 $210.28
Total

for items

Bundle Savings

Same warehouse — combine freight to save on shipping

Global FAQ

Frequently Asked Questions

General lab safety FAQs applicable to all categories and products.

Where can I find reliable liquid handling solutions?
You can find professional grade liquid management solutions at LabSafetyShop designed for efficiency safety and compliance.
How often should liquid handling equipment be maintained?
Regular inspections and cleaning should be done based on usage frequency and chemical exposure to ensure optimal performance.
Why is proper liquid waste management important?
Proper liquid waste management prevents contamination improves safety and ensures compliance with laboratory regulations.
How do liquid handling systems improve lab productivity?
They reduce manual effort minimize errors prevent spills and streamline workflows allowing lab staff to work faster and more accurately.
What are liquid handling solutions in a laboratory?
Liquid handling solutions include products used for transferring dispensing storing and disposing of liquids safely and efficiently within a lab.
Are modern laboratory safety equipment solutions sustainable?
Yes, many new products are designed with reusable materials and ecofriendly manufacturing practices while maintaining safety standards.
Recently Viewed

Pick Up Where You Left Off

Other products you recently checked out